GOLEMArchitecture·Art·Design

02.b.8How should doors, handles and thresholds be designed for independent use?

Someone entering the building needs room to approach the door, use it and carry on into the space beyond. Draw where someone stops to reach the handle or control, where they move as the leaf opens and how they cross the threshold. Check the same movement in both directions. The drawing should show the door as it will normally be used, with any second leaf locked and the furniture in its usual position.

Start with the clear opening and the usable floor area on each side. On a pull door, check the space available beside the handle when someone needs to move out of the leaf's path. If another door follows in a lobby, draw both swings and the place someone can wait between them. Test the force needed to operate the installed closer with the seals and other hardware fitted. The US Access Board's guide discusses clear opening, manoeuvring space, thresholds and hardware under the US ADA Standards. England's Approved Document M, Volume 2, sets out guidance for entrances in its own regulatory context. US Access Board, Entrances, Doors and Gates Approved Document M, Volume 2

The people using the door can help the designer judge whether its handle is usable. Test whether it can be approached from the side, operated without a tight grip and distinguished from its background. For a powered door, check the control location, the delay before closing and the space outside the swing. Agree with the operator what happens when the door or call system is out of service. Give any intercom a defined purpose and communicate the arrangements before a visitor arrives.

A threshold section can show how the two floor finishes meet and where weather protection and drainage fit. Ask whether a mat or cover plate changes the edge after the design has been agreed. In GOLEM's proposal for the Panthéon exhibition on Paralympic history, an inflated floor was part of the scenography. In a comparable commission, draw where that new surface meets doors, existing stone and temporary partitions. A continuous exhibition route depends on these junctions.

A full-size door trial lets people try it with different mobility aids, grips and reach. Include the lighting conditions expected on opening day. Give the venue the final hardware schedule and a simple method for reporting changes in closing force or faults with controls. Recheck the route if a temporary exhibition puts objects or signs beside the door.

Give GOLEM one door schedule and the floor section on each side. Ask the studio to develop the critical junction and scope a test with the installed closer, handle and controls.